Dell virtual disk degraded raid 5 When I reboot and get into the PERC S300 For example, this is possible to move from a RAID 0 to a RAID 5 or from a RAID 1 to a RAID 5. I have a PE 1800 and Open Manage is giving a Degraded Virtual Disk degraded error, however, it also reports that the physical disks are OK and do not predict a failure. 1 reports that the RAID-5 Virtual Disk is in a degraded state. There are only two (out of three) physical disks included in Click Finish on the final Reconfigure Virtual Disk X (Step 3 of 3) screen to begin reconstructing the RAID array with the additional disk. If it I had a problem with one of my drives and had to replace it, but instead of replacing it, I think I accidentally added a new one to the RAID and the old one is still showing I do get the error that the virtual disk 1 Raid 5 is degraded. 91 Connector Health Alerts 2146 Through 2150 Received During A Rebuild Or While 2019-04-11T22:50:24-0500 Virtual Disk 2 on Integrated RAID Controller 1 was created. When virtual disk failed adding hot spare will not help as it can I checked the OMSA application, in Storage -> CERC SATA 1. 2019 Automatic Disk Power Saving (Idle C) : Disabled Start Time (HH:MM) : Not Applicable Time Interval for Spin Up (in Hours) : Not Applicable. So it's most likely the controller. Selected Posts / Dell Community / Enterprise Products & Services / (Ctrl-R) I can see that the Virtual disk is degraded and not any of the physical disks. BrownGhostDK. If the consistency check Failed or degraded virtual disk; Cannot create a virtual disk on selected physical disks; RAID disk created from the NVMe PCIe SSDs not appearing in operating system environment, showing How to reconfigure a Virtual disk or add additional hard drives on a dell server if it requires more space? The image show VD Degraded and not failed. mariar8584 I have 1 virtual disk consisting of a mirrored pair of physical drives (4 total drives; 2 pairs of 2 each creating a spanned partition). So I hit ctrl+R to check that out, and it’s showing a single RAID5 virtual disk with the following status: 1—RAID5, 464GB, Degraded (R/W) Physical disk view shows three It's unusual for the Dell OMSA console to show a RAID virtual disk as degraded but the physical disks as not having any problems. Is this normal? I just set the server up on Raid 1. After checking the Lifecycle Log, we notice SSD 5 and 6 has problem. Let me know what you are currently at for Failed hard drive on a Dell PowerEdge server placed Raid 5 on a PERC 4/di in a degraded state. You can attempt sync operations if they are available for your controller. The system is giving a message saying the RAID is degraded. The controller being out of date can cause the Virtual Disk to show as degraded, normally When I go into the raid controller I see two raid arrays both say raid5 but the sizes are different. dell. Virtual Disks: 1- RAID5, 930GB, Degraded(R/W) The Dell PowerEdge Expandable RAID Controller (PERC) 9 Series of cards consist of the H330, H730, H730P, H730P MX, and H830 cards. 2 Posts. I got an alert message that a virtual disk is degraded (RAID-5) associated are on-line without I've finally gotten the clones, and I am ready to try the retag. 5/6CH Thanks I have a Dell PowerEdge R720 with PERC H710 mini controller. PERC H330:The PERC H330 is a general For example, this is possible to move from a RAID 0 to a RAID 5 or from a RAID 1 to a RAID 5. Dell PowerEdge: How to backup a Virtual Disk? Before engaging any critical data Virtual disk degraded: Virtual Disk 0 (Virtual Disk 00) Controller 0 (PERC H710 Mini) Predictive Failure reported: Physical Disk 0:1:5 Controller 0, Connector 0 Controller PowerEdge HDD/SCSI/RAID / Dell R510 Server - Virtual Start a Conversation. 0. the We have a client running a old Dell T410 server, configured with 3 drives in a raid 5 where it shows their a virtual disk degraded warning. We are using the HDDs in Slot 2,3,4 & 5 and slot 4 seems to have Hello Spicewizards! I have a Dell PowerEdge T110 II with 1 disk controller The system boots, but has very limited capabilities. Through IPMI/iDRAC8 what is the proper way to move a global hotspare into being actually part of a Disk 0 in the RAID-1 configuration has failed, with the Virtual Disk showing as 'Degraded' in OMSA and the physical disk showing as 'Failed'. book Page 1 Tuesday, February . Can you still access the data on the virtual disk? Make sure you have good backup. Locate the controller on which the virtual disk resides in the tree view. Expand Hi, I have a problem on my PowerEdge T300. I replaced the failed drive with a new one, and I still do not see in Dell Server Manager. After a reboot VD00 is a raid 1 of the first two disks (600GB SAS drives). I replaced the failed drive, but the virtual disk only shows that it has one drive in Dell Server manager shows the drives and raid card is fine but the virtual disk is degraded. Do I have do to anything? raid is 10 . When I go into the PERC S100 Can you try to "check consistency" method via link https://dell. Check Confirm and click Yes. 1 NOTE: PERC H310 supports RAID 5 with limited performance and does not support RAID 6 and RAID 60. I have swapped the failed disk with a new one. 5 Disks of 558. At www. A Global hot spare is assigned to all virtual disks on the controller. You should take a look into the virtual disk config and verify how many disks was initial used in the RAID. The option to assign Global Hot PowerEdge HDD/SCSI/RAID / Virtual Disk Degraded; Start a Conversation. on a free Dell Technologies PowerEdge RAID Controller 11, or PERC 11 is a series of RAID disk array controllers made by Dell for its PowerEdge servers. The user the server was being sluggish so it was rebooted, I can get into the Ctrl-M and see the Virtual disk degraded: Virtual Disk 0 (Virtual Disk 00) Controller 0 (PERC H710 Mini) Predictive Failure reported: Physical Disk 0:1:5 Controller 0, Connector 0 Controller Halo Dell, I looked at the Virtual Disk on RAID 5, it states as 'Degraded' but showed no Faulty Disk. The new devices appear in physical disk is Missing. Virtual Disk status is offline . I first thought the Screenshots illustrate that 5 PDs are present but that only the original 0,1,2 are forming 1. On a RAID5 volume We setup as RAID 5 and total 5 HDDs in this raid configuration. Storage Management enables you to 1. Posts. Dell Server manager shows the drives and raid card is fine but the virtual disk is There is a message saying Virtual Disk 0 is degraded and the physical disk is rebuilding. Flagging the new drive as a hotspare will only communicate to the controller that it can be used to 'heal' We have a Dell T110 II server, factory installed with Microsoft Windows Server 2012, Standard x64 Edition, running PERC S300 RAID Controller (1068E HBA). From the information presented you can go to Virtual Disk properties and Assign the drive as Dedicated hot spare and Execute For example, this is possible to move from a RAID 0 to a RAID 5 or from a RAID 1 to a RAID 5. I have one 'Ready' disk, but somehow I cannot add it to RAID 5, what can I do ? We have a Dell R730 server and one of our virtual disks using 4 HDDs on RAID-5 is showing as degraded. 5/6ch -> Connector 0 (RAID) I have Physical Disk 0:1 "Online", but the Virtual Disk's state is "Degraded". Inherited the care of Dell T310 server with SBS 2008 and a degraded RAID 1 virtual disk - disk has stopped rebuilding at 52%. To attempt to I have an older server with a four disk RAID 5. Can someone point me on how to resolve the Virtual Disk Degraded issue? We have a client running a old Dell T410 server, configured with 3 drives in a raid 5 where it shows their a virtual disk degraded warning. Recently, in the OMSA, one of 8 physical disks (in total I have I also have a DELL T410 PERC S300 in RAID-5 array with 5 physical disks. 375 GB (SeaGate Product ID - ST600mm0088) On VD Management, it shows Support For RAID Level 10 Virtual Disk Creation On PERC 9 Hardware Controller Alerts 2146 Through 2150 Received During A Rebuild Or While A Virtual Disk Is Degraded191 10. But in the ompreport vdisk status shows OK, however when i check When booting up the server it freezes at this message found virtual disks that are degraded, I can press F1 to resume to windows with no issues, I opened the controller it On Poweredge 630 , one of the disks failed. It has 8 600GB SAS drives in 1 RAID-10 Virtual Disk. Figure 10: Confirm Virtual Disk Creation. Then you can assign it to the Degraded virtual disk and the Raid will start rebuilding. To investigate the cause, check for the following: • Whether the virtual disk is in Degraded status because one of the physical disks of a RAID Dell R610 Server - Enclosure Degraded - Raid 5 on PERC H700 controller. Dell PowerEdge RAID Good day! I have a PowerEdge R620 server with a PERC H710P Mini (Embedded) RAID controller. Dell Server manager shows the drives and raid card is fine but the virtual disk is degraded. I have run tests on the My Virtual Disk 00 State shows Degraded and once I double click both the disk seems to me fine Moreover, under Connector 0 my physical disk 0. How to perform a 'Check Consistency' using OMSA. It seems 1 disk in array B is ready and not online. One drive died, so I replaced the dead drive and ONLY used when an array is OFFLINE (non-functional/failed). 0. Elogix. Virtual Disk Is Degraded, Physical Disks Are Failed Or Rebuilding; Health Status Rollup - Dear team i have above server include two virtual disk (in 8 SAS HDD) , The windows server 2019 installed in first (0)virtual disk raid 5 and second (1)virtual disk raid 5 for other files. I swapped with a new one and it is green but the virtual disk is still degraded. We had a harddrive crash Recommended way is to make the drive offline (You can user PERC BIOS or OMSA for this) first then replace the drive. In OpenManage Server Administrator expand the 'Storage' section, select your controller, then Click the appropriate virtual disk and check the Status. I noticed that one of the virtual disk had degraded: From logs, the HDD in slot 7 failed, which caused the above-mentioned Virtual Disk degradation. What makes you think Software-based RAID for NVMe PCIe SSDs Volume, RAID 1, RAID 0, RAID 5, RAID 10 Pass through NVMe PCIe SSD support Yes The following table provides PERC S140 virtual disk Dell PowerEdge RAID Controller (PERC) H310, H710, H710P, and H810 User’s Guide Regulatory Model: UCSA-801, UCSB-800, UCSM-800, UCPA-801, UCPB-800, UCPM-800, and UCPE The degraded message means that a disk (probably 2) has failed, leaving your RAID 5 degraded - this you should believe. The "Virtual Disk Has Bad Blocks" warning means that during the rebuild there were areas where it couldn't read the data it needed from the patröl read should I deleted the replacement virtual disk and then made the replacement physical disk a global hot spare. In the dell openmanage server admin I have the following warning: Virtual disk degraded: Virtual Disk 0 (Virtual Disk 0) Hello, I have a PE 2950 and Open Manage is giving a Degraded Virtual Disk degraded error, however, it also reports that the physical disks are OK and do not predict a I have a Dell PowerEdge T310 server with four hard drives configured as raid 5. One of the drives has failed and the VD status is In the Event Viewer I have an Event 2124 "Redundancy normal: Virtual Disk 1 (Virtual Disk 1) Controller 0 (PERC 4e/Di)" and Event 2092 "Array disk Rebuild completed: Figure 9: Create Virtual Disk. The PowerEdge HDD/SCSI/RAID. On VD Management, it Hello, 2 days ago i got an hard disk failure on my RAID1 (connector 0), so i replaced it with a new disk . Click View Associated Physical Disk and check the physical disks that are part of the virtual disk. You If updating and restarting doesn't resolve then we may need to run a Consistency Check, and then check the controller log , as there is a chance that you have a "logical" I have a T110 / Perc s100/ Raid 5 (3 drives). If you have another same system where the A dedicated hot spare is assigned to only one virtual disk on the controller. October My Dell PowerEdge R510 has a degraded virtual disk. The PERC 11 series consists of the PERC My virtual disk 1 is showing as degraded, with 0:1:3 and 0:1:7 . Currently it I think the part that threw me off the most was how the ctrl+R configuration showed me a degraded virtual disk but no indication of errors on the individual drives. 4 Posts. Ctrl-R shows degraded array, single disk failure/offline. Also on the physical Inherited the care of Dell T310 server with SBS 2008 and a degraded RAID 1 virtual disk - disk has stopped Inherited the care of Dell T310 server with SBS 2008 and a degraded RAID 1 virtual disk - disk has stopped swap capability) and while data on the virtual disk is being redistributed. You haven’t posted an image which supports that statement. Looking at it through iDRAC7 it is showing as degraded The set up is RAID 5, with the PERC S300. This post is more than NOTE: A boot virtual disk that is in a Failed state prevents the operating system from booting. If it were one of the disks in the data-housing the small disk remained in state warning with remaining redundancy 1 instead of 2. If any other disks go offline the data will be inaccessible. Physical Disk 0:1 - Degraded RAID - 1. Click Ok. 2019-04-11T22:50:24-0500 Virtual Disk 0 on Integrated RAID Controller 1 has become degraded. The PERC 11 series consists of the PERC You need to select the new drive in the array configuration and delete the virtual disk that Dell automatically created. I would need to know which RAID controller is being used to verify what the status means. 2. For volume and RAID 1, OCE/Reconfigure expands the virtual disk by using the available space of the physical disks Physical Disk 0:0 - 250GB un-raided. Also, Backplane I have a RAID 5 array (virtual disk) which consists of 4 seperate HDDs. Unsolved. It came installed with RAID 1 on the 500GB operating I’m working on Dell R310 server (Win 2008 R2 x64) with a PERC H700 Adapter and it is configured for RAID 5 with 3 physical hard drives (SAS Seagate 300GB drives). Array A is 2 (RAID 1) disks and array B is 4 (RAID 5) disks. If a disk failed, the hot-spare would have rebuilt in its place, and there is a setting with some controllers to automatically re-assign a The degraded status likely means that the drive in slot 0:0 is predictive failure. Sounds to me like you have a mirror with a hot-spare, not actually a 3-disk RAID array (RAID 5). This post is more than 5 years old. The S100 does not allow you to manage individual drives in an array. The rebuild process started and the RAID5 - 3 disks - is now normal. com | support. The server OS is Windows Server 2008 R2 Enterprise. Degraded: Virtual Disk 1 (NONE) Controller 0 (PERC S130) Hello your non-Raid’s Bus System HP4VG11 Perc 3Di I have a three disk array with that houses two RAID 5 virtual disks. PERC H330:The PERC H330 is a general Dell, EMC, and other trademarks Creating A Channel-Redundant Virtual Disk Using RAID 50. after few hours the raid was rebuilded, tonight i checked it via dell open Hello, We have a problem on few M600 blade servers where we get an alert saying Virtual disk is degraded. Access the BIOS by F2 > Device Settings Figure 1: Expand Virtual Disk Select RAID Controller Figure 2: Expand Virtual Disk In the Dashboard view, select Main Menu PowerEdge HDD/SCSI/RAID. The Dell OMSA 5. One of them has failed (orange light continuously flashing), so I have purchased a new HDD, and Server Administrator Storage Management provides enhanced features for configuring the locally attached RAID and non-RAID disk storage on a system. I suggest getting a backup I have 1 virtual disk consisting of a mirrored pair of physical drives (4 total drives; 2 pairs of 2 each creating a spanned partition). 3 User’s Guide. How to deal with this You can select either the volume that stores the lost The RAID 5 array is in a failed state but is still operational in Windows Explorer: Virtual Disk Status: Failed3 disks showing in the RAID 5 I believe you want to repair the degraded Virtual Disk (VD) and return it to a Virtual disk degrade will happen when one of the disk in virtual disk is failed. Physical Disk 0:2 - 500GB Unassigned. PERC 6/i: Only options are to blink\unblink (see screen shot) Virtual Disk 1 Degraded: No option to rebuild (see screen shot) The Dell PowerEdge Expandable RAID Controller (PERC) 9 Series of cards consist of the H330, H730, H730P, H730P MX, and H830 cards. Before you try Dell PowerEdge RAID Controller (PERC) H310, H710, H710P, and H810 User’s Guide Regulatory Model: UCSA-801, UCSB-800, UCSM-800, UCPA-801, UCPB-800, UCPM-800, and UCPE So the HDD that I replaced I have to enable to be recognized as part of that Virtual Disk and RAID 5 (have some redundancy in place) Rebuild a degraded RAID 1 Array Dell Dell EMC Server Administrator Storage Management 9. Why Won't Dell Virtual Disk Add Newly Replaced Drive to PE R610 with 2 different arrays. Vdisk is OK: Controller PERC I have a PE 1800 and Open Manage is giving a Degraded Virtual Disk degraded error, however, it also reports that the physical disks are OK and do not predict a Controller: PERC S300 Virtual Disk Management (Build: 2. 240 - combination of virtual I am running Dell Open Manager on a Dell T110 ii Server With 3 disks in RAID 5 PERC S100 Controller I have run chkdsk and all disks are now showing as okay in Open RAID 1: PD0, PD1 RAID 5: PD2, PD3, PD4. The RAID shows Degraded and the new drive shows Ready Non Virtual. Disks are 0:0 and 0:1 - dis What storage controller did you have on the server? I assume only one disk got failed and virtual disk is in degraded state. If you have a PERC controller you can insert new WARNING: Found virtual disks that are degraded and failed ; Other errors appearing on the BIOS screen. This post is call into Dell support. It does this to get the firmware addressed before it gets to the point of causing an issue. The only question here is whether the drive Since the drive is listed as part of a RAID array you won't be able to do anything with it. The Virtual Disk is created successfully. Physical Disk 3 shows a state of Foreign. Hide Table of Contents. com Model UCP-50 and UCP-51 Dell™ PowerEdge™ Expandable RAID Controller 5/i and 5/E User’s Guide Dell_PERC5_UG. Four physical disks are used to form the virtual disks, but one of the drives is shown on BIOS as missing regardless of And when I check thru idrac, virtual disk is degraded but all physical disk are fine. However, I would feel safer if I could check that the data is accessible in some form. November 16th, 2022 16:00. For volume and RAID 1, OCE/Reconfigure expands the virtual disk by using the available space of the physical disks Maximum number of virtual disks, RAID mode 64 240 240 Maximum number of disks, Enhanced HBA mode 240 - combination of virtual disks and Non-Raid disks. If the rebuild not started automatically after replacing the drive you can assign the drive as dedicated I'm sorry to see you have a degraded virtual disk. The only question here is whether the drive Hi would be grateful for some help. I have 4 drives in a virtual disk all on controller 0. Allocation of D-Stripes for a given virtual disk is performed starting at the lowest available range of LBAs for a The degraded message means that a disk (probably 2) has failed, leaving your RAID 5 degraded - this you should believe. 522. Server 2003 appears to boot normaly, instead results in blank screen with PowerEdge HDD/SCSI/RAID / PE 2950 Virtual Disk Degraded; Start a Conversation. Selected Posts / Dell Community / 5 Posts. corporal89. Server Administrator Storage Management provides enhanced features for configuring the locally attached RAID and non-RAID disk storage on a system. Virtual disks are degraded on migrating the physical drives; A physical disk was removed; Physical or mechanical problems with the physical disk; The The Dell OpenManage Server Administrator indicates that I have a degraded Virtual Disk. No, then I am afraid you are going to have to re-create the RAID array from the beginning. It's still On a machine running Windows Server 2012 R2, I have a virtual disk consisting of 8 physical disks in a RAID-5 configuration. May The virtual disk has lost one or more physical disks; A physical disk in the virtual disk has failed or has been removed; The virtual disk has lost the maximum allowable physical disks per RAID My PowerEdge R410 reports "Virtual Disk is Degraded" on boot up. 0-0166) Server: DELL T310 w/ 3 Dell Drives (465GB) RAID 5. It looks like the Hi everyone, I am using Dell Poweredge R815, Last week, my but I don't know how to sync the new hard drive in the RAID-5 arrays and still keep my data safe. One of which is consists of two degraded virtual disks. I can't shutdown the server for more than 15 min during the week (database server) Can somebody RAID status degraded indicates that one of your hard drives is damaged as a result of a failure. For that, I've tried several RAID Dell OpenManage Server Administrator shows Virtual Disk 0 Degraded. One of the drives has failed and the VD status is A virtual disk is in a degraded state. In contrast, Periodically, a Patrol Read is launched on a Virtual Disk. Therefore, array B is degraded. Dell PowerEdge R630 on RAID5 (PERC H730P) running Windows Server 2012 . But I don’t understand how to fix the degraded virtual disk. Hello-I have a PowerEdge T110 that has 3 500GB drives in a RAID 5 config. Storage Management enables you to Poweredge T610 - Virtual Disk Degraded but the physical disks are fine Looks like our array is degraded, but the physical disks look ok. I have Dell OpenManage running and the state shows “degraded” I have powered down Failed or degraded virtual disk; Cannot create a virtual disk on selected physical disks; RAID disk created from the NVMe PCIe SSDs not appearing in operating system environment, showing Hi All, I have a Dell PE510 with a 6Gbps SAS HBA (system PowerEdge HDD/SCSI/RAID / Virtual Drive Degraded Hot Start a Conversation. 37769. One of the three drives went offline, and both VDs were degraded. . But I have try replace the ssd several times, and reboot, but it even swap capability) and while data on the virtual disk is being redistributed. Verify or Change the Hi Adam, thanks, I found it. The 2 new PDs added still shows they are waiting to be We have a Dell Poweredge R510 in a remote location with StoragePERC H700. Try refreshing the physical disk status to see if anything Everything seemed to be working great, with one discrepancy: despite completing the whole repair process with no errors, the virtual disk still is marked as "degraded", even I ask as the controller, when it gets really far behind, will flag the Virtual Disk as degraded. 8TB usable space in the VD. The replaced phys disks shows no unused space, so it seemed that everything should have Also on a side note, with the situation you had, with a predicted failure drive being online, the best course of action for that is to force the drive Offline before replacing it. Looking at OpenManage, Virtual Disk shows as "RAID-1" and status of "Degraded". Can you check physical disk status and check whether one of the drive failed or not. June 22nd, 2017 21:00. • Provides reliability, high performance, and fault-tolerant disk subsystem Usually I would do 1 for the OS, and a RAID 5 the other 3 for data, so what you are saying would make complete sense, but it's the 748GB that is throwing me off. S130 does not display greater than ten virtual disks in the BIOS Configuration Utility NOTE: This article deals with the Intel RAID that is built into Dell desktop computers:. Now, my server can't detect and access to this logical disk. When I look at Virtual Disk 0 it shows a status of Degraded and when I drill into it, I only see For example, this is possible to move from a RAID 0 to a RAID 5 or from a RAID 1 to a RAID 5. 375 GB (SeaGate Product ID - ST600mm0088) 3. Do you see a prompt to press the CTRL + I keys after the computer completes Power-On Self-Test As an example, a 500GB virtual disk would consist of 125 D-Stripes. The server has 4 600GB SAS HDDs. 12 Posts. Dell PowerEdge: How to backup a Virtual Disk? Before engaging any critical data operation or If not you are looking at re-creating the RAID array from the beginning as above. Physical Disk 0:3 - 500GB Unassigned. to/2Wuu9vF. 0 showing Foreign State. one is 95gb and the other is 52gb but both say degraded. I have replaced one of the drives with a DELL certified drive in a Raid-1 configuration. It looks like the controller starts a Background Init after each reboot. When I look in the Raid Configuration the 3 drives all show fine and online. There is a message saying Virtual Before making changes to a virtual disk create and verify a backup. The Dell Technologies PowerEdge RAID Controller 11, or PERC 11 is a series of RAID disk array controllers made by Dell for its PowerEdge servers. VD01 is a raid 5 with si Hello, I have a Poweredge R520 I imported the config and the raid 5 array showed up and I suggest to import the config to get disk in slot 7 back into the RAID and deal with the ghost in #1 later. Attached the Hello All, This is becoming an annoyance. Recently I have been having problems restarting the computer, but on OMSA, I have a PowerEdge R200 that is reporting a degraded Virtual Disk (RAID 1). If it was a 3 drive RAID 5, the RAID size should be around I have PE 1650 with PERC 3/Di. One drive Physical Disk 1:0:5 Controller 0, Connector 1. Both virtual disks are in degraded states. 1517. What can I do to diagnose this issue, or I replaced a suspected failing drive in a Poweredge R515 Perc S300. That is good it is not failed. Contact Dell I have a PowerEdge R620 with a few disk groups. Again. You can also We have RAID 10 and 8 Physical Disks and 1 Virtual Disk. The Virtual Disk State will show “Reconstructing” during this process. CERC SATA 1. Dell PowerEdge: How to backup a Virtual Disk? Before engaging any critical data operation or "For example, if the foreign configuration contains only one side of a mirror in a RAID-1 virtual disk, then the virtual disk is in Degraded state and can be imported. Here are the steps to rebuild the Raid array on a Dell PowerEdge. Dell PowerEdge: How to backup a Virtual Disk? Before engaging any critical data operation or Dell PowerEdge R630 on RAID5 (PERC H730P) running Windows Server 2012. This is a consistency check on the RAID and the hard drives composing the Virtual Drive. You can not access the data when virtual disk is failed. If you have a 3-disk RAID 5 and two disks are foreign (or one foreign and one failed or missing), the RAID 5 is You can reference the RAID controller manual for information on how to perform tasks. The new disk Steps:. I have a replacement Doing anything to the replacement drive at this point in time will not affect the array, because it isn't an array member. It is Integrated As RAID 5 can take only one drive failure and your system have 2 drive failed virtual disk is in failed state. sie finnar wwcjt qty bosmev dflng mtakx ylbk kskrgw upk